JUAL intelligent micro differential pressure 3051 sensor 4-20mA hart

JUAL intelligent micro differential pressure 3051 sensor 4-20mA hart
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgllo_cAI8mV9X_fhz3dlNbsWXClzko3rIg0jWCQzayMfm8n1g6SBiHvc1vwNJmQwM6kpCXpikU1fWrloCwnM3CmRbPfKN-9UI5Tlid53lnGLQpw3Prb4eR1GUHDVZSwCiGtJ_xQQAQpIVX/s72-c/TUF-2000B+TM-1+Ultrasonic+flow+meter+DN50mm-DN700mm+wall+mounted.jpg
  • intelligent micro differential pressure 3051 sensor 4-20mA hart
  • The differential pressure transmitter adopts microprocessor technology for temperature compensation and nonlinear compensation, which greatly improves the measurement accuracy of the instrument, improves the temperature characteristics, expands the range ratio, adds intelligent configuration functions, and further meets the high reliability of industrial field instruments. , high stability requirements. The key components and parts are imported, and the whole machine is delivered after rigorous testing. With advanced design principles, reliable product quality, complete specifications, easy installation and use.

  • Zero and range:
  • It can be adjusted with the local range and zero button, or remotely with a HART handheld smart terminal. Zero positive and negative migration:
  • When zero-negative migration occurs, the lower quantum must be greater than or equal to -URL; when the zero is being migrated, the upper quantum must be less than or equal to +URL. The inspection range must be greater than or equal to the minimum range.

  • Output signal: DC4-20mA+HART protocol
  • Output method: Linear output Square root output (can be remotely adjusted by configuration software)
  • Damping time constant: The time constant is adjustable in 0.1 second increments from a minimum of 32 seconds. If the damping time is 0, the default is 0.1.
  • Ambient temperature limit: Normal -40 to 85°C LCD Head -20 to 70°C
  • Process temperature limit: -40 to 104°C
  • Storage temperature limit: -40 to 85°C
  • Humidity: 0-95% relative humidity
  • Change in volume: less than 0.01in3 (0.16cm) (zero reference calibration range, reference fluid, silicone fluid, 316L stainless steel diaphragm)
  • Accuracy: Range ratio <5:1:≤±0.1 % FS
  • Ambient temperature effect: -29 to 85°C
  • Zero point error: 0.5%URL/56°C
  • Total error: (0.5% URL+0.2% calibration range) /56°C
  • Power supply range: 12~36VDC

TOKO MARGA SETIA SURVEY
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS Magellan, Alat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name       : tatang survey
Alamat     : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email      : tatangms409@gmail.com
Telp       : 082124100046 / 083892207786
WhatsApp   :082124100046
Fax : (021)22054159
Web        : www.margasetiaonleneshoop.com
             www.nandarsurvey.com
             www.distributorsirinejakarta.com
Share this product :

Post a Comment

Pages (26)1234567 Next
 
Support : Creating Website | Tatang Survey | Redesigned :Tatang Survey
Copyright © 2011. Nandar Marga Setia Survey - All Rights Reserved
Margasetia Created by Creating Website Published by tatang survey
Proudly powered by Blogger