PROCEQ Profoscope + Portable Rebar Locator
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjbO3IYQs102p0Ffo4BKD_ir6aN6AmBHRq6m6HDyKOckSgXmuN-JeI30XYjiT8eG_ttegOyccoawTfi1A6UEoyYuoMGoUTQOXik23P8Ja7z8aMeyzMJDGf-_X01lAYAjWYCOzj3fDV5Kqlt/s72-c/Jual+Rebar+Locator+Profoscope.jpg
TOKO MARGA SETIA SURVEY
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS Magellan, Alat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name : TATANG SURVEY
Alamat : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email : tatangms409@gmail.com
Telp : 082124100046
WhatsApp :082124100046
The Profoscope is a versatile, fully-integrated rebar detector and cover meter with a unique real-time rebar visualization allowing the user to actually “ SEE” the location of the rebar beneath the concrete surface to a maximum depth of 180 mm. This is coupled with rebar-proximity indicators and optical and acoustical locating aids.
Rebar diameter can also be estimated within the specified testing range. The Profoscope combines these unique features in a compact, light device that allows the user to operate this rebar detector with one hand making the task of locating rebars a simple and efficient process. In addition, Proceq’ s rebar detector convinces through its intuitive user interface making rebar detection easy.
Key Features
A rebar detector with real-time visualization of the rebars beneath the instrument
Visual indication of rebars in close proximity
The Profoscope is a rebar detector with the ability to identify the mid-point between rebars as well as the orientation of rebars
Optical and acoustical indication of rebar location and minimum cover alert
This rebar detector offers neighboring bar correction
Regional settings ( metric, imperial)
Cordless and single handed operation
Specification:
Power supply 2 x 1.5 V AA ( LR6) batteries
Voltage range 3.6 V to 1.8 V
Battery lifetime
Backlight off > 50 hr
Backlight on > 15 hr
Time outs
Sleep mode 30 s
Auto shut down 120 s
Environmental conditions
Temperature range -10° C to 60° C ( 14° to 140° F)
Humidity range 0 to 100 % rH
Protection range IP54
Standards and regulations applied BS 1881 part 204; DIN 1045; SN 505 262; DGZfP B2